Product Description
V40 EE FC3 LD 628 99 36 Detex V40 Series Rim Exit Device — Delayed Egress, Fire Command Input, Less Dogging, Satin Aluminum Clear Anodized
Memory care facilities, retail loss prevention, and secured government areas all need the same thing: a code-compliant way to delay exit without trapping anyone in a fire. The Detex V40 delayed egress device provides a 15-second hold (field-selectable to 30) with audible and visual warning — then releases clean.
Technical Specifications
| SKU | V40 EE FC3 LD 628 99 36 |
| Series | Detex V40 Value Series |
| Mount Type | Rim |
| Stile | Wide Stile |
| Grade | ANSI/BHMA Grade 1 |
| Function | Delayed Egress, Fire Command Input, Less Dogging |
| Finish | Satin Aluminum Clear Anodized (628) |
| Strike | 99 Surface Strike |
| Device Length | 36" |
| Power | 24VAC/DC |
Compliance and Codes
- ANSI/BHMA A156.3 Grade 1 — highest commercial grade for panic hardware. Tested to 1,000,000 cycles.
- UL 305 — listed panic hardware for means of egress.
- NFPA 101 Life Safety Code — compliant delayed egress per Section 7.2.1.6.
- IBC 1010.1.4.3 — meets International Building Code delayed egress requirements.
- ADA Compliant — operates with less than 15 pounds of force.
Function Details
- 15-second delayed egress (field-selectable to 30 seconds) with audible/visual warning. Code-compliant for memory care, retail loss prevention, and secured areas. Releases immediately on fire alarm signal.
- Includes fire command (FC3) input for integration with building fire alarm panel. Releases device on alarm signal.
- No dogging mechanism — door latches every time it closes. Required for fire-rated openings where code prohibits dogging.
What's in the Box
- Detex V40 Rim Exit Device
- 99 Surface Strike
- Mounting hardware and template
- Installation instructions
- Delayed egress warning sign (required by code)
Note: Power supply sold separately — 24VAC/DC required. We recommend Altronix or similar UL-listed supply.
Pro-Installer FAQ
Can this device be cut down for narrower doors?
Yes, the pushbar can be field-cut for doors narrower than standard width. Measure carefully and cut from the hinge end only. The lock stile end must remain factory length for proper strike engagement.
Can the delay be changed from 15 to 30 seconds?
Yes, the device is field-selectable between 15 and 30 seconds. However, a 30-second delay requires written approval from your local Authority Having Jurisdiction (AHJ) or Fire Marshal before installation.
Why would I choose Less Dogging?
LD (Less Dogging) is required on fire-rated door openings where code prohibits holding the latch open. Even if the device itself isn't fire-rated, the opening may require LD based on the door's fire label.
Why Lock Depot? We specialize in commercial exit hardware. Factory-sealed, Grade 1 Detex devices ship same day on available stock. Need help specifying the right device for your opening? Call us.