Falcon RX25 or MEL25: Request to Exit or Electric Latch
Posted by Kent on 27th Nov 2026
Two ways to make a panic bar part of an access control system
A plain exit device is a mechanical thing. You push the bar, the latch pulls back, you walk out. The system never hears about it. The moment the building adds a card reader, a door monitor or a remote release, someone has to decide how the exit device talks to it. Falcon sells two versions of the 25 Series rim device for that job, and they do different things. The RX25 tells the system when the bar is pushed. The MEL25 lets the system pull the latch back for you.
They are easy to mix up on a quote, because the part numbers differ by a letter or two and the descriptions read alike. This guide sorts them out so the right one lands on the door. If you are still sizing up the 25 against the 24, read that comparison first.
What both versions share
Per the catalog listings, both are 25 Series rim-mounted devices, a surface-applied push bar on the door face. Both are exit-only: a push-pad on the inside dogs and retracts the latch, and the outside face is blank, so there is nothing to operate from outside. Both are listed as tested to ANSI/BHMA A156.3 Grade 1 for the Falcon 24/25 Series, and both are non-fire-rated in the versions below. The fire rated versions of each are a separate family, and we cover them in another piece.
RX25: request to exit
The listing says the RX configuration adds a built-in request-to-exit switch for access-control monitoring. In practice, that is a switch inside the device that changes state when someone pushes the bar. The access control panel reads it and knows the door was opened from the inside on purpose.
Why does that matter? A door with a reader on the outside and a magnetic lock or electric strike will raise an alarm every time someone walks out, unless the panel knows the exit was legitimate. The request-to-exit signal tells it. No signal, no shunt, and the panel reports a forced door.
The catalog carries RX25-R-EO-US28-3 in anodized aluminum and RX25-R-EO-US32D-3 in satin stainless steel.
Remember what the switch does not do. It does not unlock anything and it does not retract the latch for anyone. It reports. The listing gives no switch rating, contact type or wire count, so get that from us before the electrician pulls cable.
MEL25: motorized electric latch retraction
The listing says the MEL configuration adds motorized electric latch retraction, described as quiet, remote unlatching. A motor inside the device pulls the latch back when it gets a signal. A button at the front desk, a reader, a fire panel input: whatever you wire to it can pull the latch and let the door open without anyone touching the bar.
That is a different job. It suits a door that someone has to be able to release from across the building, or a door that should open for a delivery on a schedule. The catalog lists MEL25-R-EO-US28-3 in anodized aluminum and MEL25-R-EO-US32D-3 in satin stainless steel.
A motorized device needs power, and the listing does not give a voltage, a current draw or a power supply requirement. Do not size a supply from a guess. Ask us for the figure, and plan on running a power conductor to the door before it goes in.
The mistake I see most
Someone orders an MEL25 because they want the door monitored, then finds out nothing reports the push. Or someone orders an RX25 because they want a remote release, then finds out the latch only moves when the bar does. Each version does one thing. If you need both, there is a combined version: RXMEL25-R-EO-US28-3. Its listing says it adds motorized electric latch retraction and a built-in request-to-exit switch. The extra letters in the part number are the tell.
A quick way to choose
- The access control panel must know when the bar is pushed: RX25.
- The latch must release remotely without touching the bar: MEL25.
- Both: RXMEL25.
- Neither, just a clean exit: the plain 25 or the dogging versions.
If the choice you need is about keeping the door held open, that is dogging, and it is a different decision. The piece on when to spec the 25 helps frame the whole range.
What the listings do not tell you
- No voltage or current for the MEL motor.
- No switch type or rating for the RX contact.
- No bar length, latch throw or strike. The strike is a separate part, and a rim device needs one that matches.
- No explanation of the -3 on the end of the part number. Some versions end in -4. I will not guess at the meaning. Give us the door width and we will confirm.
One catalog quirk: the RX24 version of this device calls itself a 25 Series in its title and text, so if you want the 24 Series, ask us to confirm the part number before you order.
Finish
Both come in anodized aluminum and satin stainless steel in the versions above, plus a chrome finish. Match the other doors in the corridor. Mixed finishes on a panic bar line look worse than any other hardware mismatch, because the bars are the biggest metal on the door.
See the whole line on the Falcon page. Send us the door, the access control, and what should happen when someone pushes the bar, and we will give you the part number.