Sargent 8800 Prefixes 12, 55, 56: Fire Label, REX, Retraction

Sargent 8800 Prefixes 12, 55, 56: Fire Label, REX, Retraction

Posted by Kent on 28th Nov 2026

What the number in front of a Sargent 8800 part tells you

Pull up the Sargent 8800 listings and you will see part numbers that start with 12-, 55-, 56-, or a string of them: 12-55-56-. Those numbers are not a model change. They are factory options on the same 80 Series rim exit device, and each one changes what you have to do at the door before and after install.

This guide reads those prefixes the way the listings define them. I do not go past what the listings state. Where a number you want is not in our data, I say so.

12-: fire label

The 12- prefix means a UL fire label exit device for labeled openings. 12-8810F-862-32D is the exit-only 8810 with the 862 pull in that form. The listing carries two warnings. A fire exit device has no mechanical dogging. And a non-labeled device does not belong on a fire-rated door.

That second point decides the order. If the door is in a rated opening, the 12- is not an upgrade you choose, it is the part. If the door is not rated, the 12- gives you nothing extra and you lose the hex-key dogging that the plain device offers. Whether the opening needs the label is the AHJ's call. We sell the device.

55-: request to exit

The 55- prefix is a signal switch in the rail. The listing states that pushing the bar sends a signal to your access control or alarm system. It is a request-to-exit contact built into the device.

The point is simple. When a person pushes the bar on an access-controlled door, the system needs to know the opening is an exit and not a forced entry. 55-8810F-862-32D carries that switch in the exit-only configuration. The passage versions carry it too: 55-8815F-ETL-RHR-32D is the passage function with the signal switch, and 55-8815F-ETL-LHR-32D is its left hand reverse mate. The listings do not state the switch contact rating or voltage. Get that from Sargent's literature before you wire it to a panel.

56-: electric latch retraction

The 56- prefix is a motor in the rail that retracts the latchbolt on a signal from your access control. The listing says Sargent supplies this function factory installed or as its M56A retrofit kit for the standard rail. It gives a minimum door width of 26 in for a narrow stile and 28 in for a wide stile.

The detail that gets missed is power. The listing is direct about it: the device needs low-voltage power at the door, so plan the power supply and the wire transfer before you order. A door with a power transfer hinge or a wire loop already in it is easy. A door with nothing is a drilling job. Make that call before the part arrives.

Two more notes from the listings. The 56- configuration has no hex-key dogging. And the effect at the outside depends on trim. On an exit-only device with the 862, retracting the latch lets the pull open the door. On the passage 8815, such as 56-8815G-ETL-RHR-32D on a 48 in rail, the lever always operates, so electric retraction there is a convenience and not a lock-out. 56-8815F-ETL-RHR-32D is the 36 in rail version with the same option.

Stacked prefixes

You can have more than one. The listings include 12-55-56-8810F-862-32D for fire label, request to exit and electric retraction together, and 12-56-8810F-862-32D for fire label and retraction. The 12-55-56 listing states there is no hex-key dogging on that configuration.

Keep the numbers in the order the part number prints them. Do not reshuffle. If you want a combination that is not on the site, call and we will check whether Sargent builds it before you spend time on a drawing.

What the prefix does not tell you

The numbers describe function, not finish or door fit. Finish is the code on the tail of the part, 32D for satin stainless and 10BE for dark bronze on these listings. Rail length is the letter after the device number: F is 36 in and G is 48 in. The older 8800 listings in our catalog follow a different template and say less. Treat the definitions above as covering the newer, detailed listings, and ask us if you are working from an older part.

Other Sargent lines use their own option systems, and we do not state those here. Browse the Sargent hub, or see how the narrow stile 80 Series differs from the wide-stile 8800 before you pick a device for an aluminum door.

Common questions

Does a 12- device have dogging?

No. The listing says a fire exit device has no mechanical dogging. If you need a door held retracted, plan another method and check it with your AHJ.

Can the 55- and 56- run together?

Yes. The listings include 55-56 versions in satin stainless and dark bronze. Wire the signal switch and the motor to your access control as separate circuits.

How wide does the door need to be for 56-?

The listing states a minimum of 26 in for a narrow stile and 28 in for a wide stile.

Does the 56- lock the door?

No. It retracts the latchbolt on a signal. Whether the outside lever or pull then opens the door depends on the trim you ordered.

Do these prefixes apply to every Sargent exit device?

The definitions above come from the Sargent 8800 listings. We do not state them for other Sargent lines, so call us for the line you need.