Simplex 5021RWL vs 5021CWL: Sargent or Corbin Russwin Core
Posted by Kent on 14th Nov 2026
The two letters that decide which key opens it
A Simplex 5021 pushbutton lock lets people in with a code. The key override is for the locksmith, the facilities crew and the fire department's lockbox plan: the door has to open for somebody who does not know the code. That override is a large format interchangeable core, and the core has to match the keyway system already running in the building. On the Simplex 5021 the third letter in the model number tells you which system: R and the lock is prepped for a Sargent LFIC, C and it is prepped for a Corbin Russwin LFIC.
The full model reads 5021, then R or C, then W, then L or K. The titles in our catalog spell out the two ends of that: the L models are the lever versions and the K models are the knob versions. The catalog does not explain the W, so we do not guess at it. Order by the whole string and you get what is on the label.
The four models side by side
| Model | Trim | Override core | Example |
|---|---|---|---|
| 5021RWL | Lever | Sargent LFIC | 5021RWL-026-41 |
| 5021RWK | Knob | Sargent LFIC | 5021RWK-026-41 |
| 5021CWL | Lever | Corbin Russwin LFIC | 5021CWL-026-41 |
| 5021CWK | Knob | Corbin Russwin LFIC | 5021CWK-026-41 |
All four are the same lock underneath. The listings carry the same specifications: ANSI/BHMA Grade 1, a 2-3/4 in. backset, a 1/2 in. latch throw, a door thickness range of 1-3/8 in. to 2-1/4 in., a 2-1/8 in. cross bore and a 1 in. edge bore. The lock is non-handed and field reversible. The listing says it ships left hand and swaps to right hand on site.
The core is not in the box
Every one of these listings says the same thing: prepped for the LFIC key override, core sold separately. You are buying a lock that has a cavity for a core, not a lock that has one. That is the single most common surprise on this model. The pushbutton works the day it is installed; the key override does not exist until somebody installs a core.
The core is the part that has to match your keying. If the building already runs Sargent cores on its other doors, take the R model. If the building runs Corbin Russwin, take the C model. If you are not sure, check a lock you know is in the system and confirm the maker before you order. Each listing preps the lock for one maker's core, so do not assume a core from the other maker crosses over. Order on the maker's name, not on a hunch.
For picking the Sargent keyway letter, see the Sargent 6300 core guide. For a Schlage core on the same lock, a different model exists and is covered in the 5021SWL piece.
Lever or knob
The lever models are the ones the listing calls ADA-compliant. That is what a corridor, a clinic or a public-facing office needs, because a lever opens with a closed fist or an elbow and a knob does not.
The knob listings carry a quirk worth knowing about. The knob titles say knob, and the trim field says knob, but the feature bullets on those pages were copied from the lever listing and still say "ADA-compliant lever design." Both statements cannot be true of the same lock. Treat the title and the trim field as the real description. If you are specifying for a door that falls under accessibility rules, take the lever model. If the door is a back-of-house mechanical room, a knob is a reasonable choice.
Three finishes in the catalog
Each of the four models is listed in the same three finishes, and the last digits in the model number tell you which one:
- -026-41: Bright Chrome, US26/625
- -03-41: Bright Brass, as in 5021RWL-03-41 and 5021CWL-03-41
- -04-41: Satin Brass, as in 5021RWL-04-41 and 5021CWL-04-41
The catalog does not say what the trailing 41 stands for, and we are not going to decode it. It is the same on every model here. Match the finish to the other hardware on the opening and leave the 41 alone.
What stays the same either way
- All-mechanical operation: no batteries and no wiring.
- A single access combination with thousands of possible codes.
- The combination can be changed at the keypad without taking the lock off the door.
- Vandal-resistant solid metal pushbuttons.
- Described as weather-resistant for indoor or outdoor installation.
- A 3 year warranty.
Those are the manufacturer's statements as they appear on the listings. We have not listed the code count or an exact number of buttons because the catalog does not give them.
Before you order
- Confirm which maker's cores the building already runs. Sargent means R. Corbin Russwin means C.
- Decide lever or knob. Public or accessibility-governed opening: lever.
- Check the door: 1-3/8 in. to 2-1/4 in. thick, 2-1/8 in. cross bore, 1 in. edge bore, 2-3/4 in. backset.
- Add the core to the order. It is a separate line.
- Pick the finish from the three listed.
If your door has a 2-3/8 in. backset, or you want a different function, the 5021, 5022 and 5025 comparison covers backset and latch throw. The rest of the line is on the Simplex page.
Common questions
Does the lock come with a core?
No. The listings say the core is sold separately.
Can I put a Corbin Russwin core in an R model?
The listings prep the R models for a Sargent LFIC and the C models for a Corbin Russwin LFIC. Match the letter to the core and call us if you want to do anything else.
What is the difference between L and K?
L is the lever version and K is the knob version, according to the catalog titles.
Is it handed?
No. It is non-handed and field reversible. It ships left hand and converts on site.
Do I need power?
No. It is all mechanical.