Seven M32s, one lock
Pull up the Securitron M32 and you get M32B, M32D, M32F, M32BD, M32FB, M32FD and M32FBD, each with its own page and its own stock count. It looks like seven locks. It is one 600 lb magnalock with options added a letter at a time, and the letters mean the same thing on every part.
If you have not yet settled on the M32 itself, start with our holding force article on the M62, M32 and M34R. This piece covers the next question: given the M32, which letters go on the end of the part number?
What every M32 shares
The listings describe the same lock under every suffix. It is a 600 lb holding force magnalock with automatic dual voltage, so nothing is set in the field between 12 and 24 volts. The feature list gives ten feet of jacketed, stranded conductor, collapsing blind nuts that mount to the door frame, fully sealed hardware for inside or outside use, an instant release circuit with no residual magnetism, and a noise suppression MOV. The ferrous metal is plated against rust, and the lock carries Securitron's lifetime replacement warranty.
The listing's own advice on where to use it is plain: places where physical assault on the door is not expected. A monitored secured area, or an interior door you need closed to honest prying eyes. If the door will be kicked, step up to the 1,200 lb class. Our M62 suffix guide reads the same letters on that lock.
What the listings do not give us: current draw at 12 or 24 volts, the overall body dimensions, or the mounting space required. We will not estimate those. Pull them from the installation sheet before you cut a header.
The letters, one at a time
Each letter is defined by the product name in our catalog, not guessed from the part number.
| Part | Letters | What the name says it adds |
|---|---|---|
| M32B | B | Magnetic bond sensor |
| M32D | D | Door position switch |
| M32F | F | Face drilled holes |
| M32BD | B + D | Bond sensor and door position switch |
| M32FB | F + B | Face drilled holes and bond sensor |
| M32FD | F + D | Face drilled holes and door position switch |
| M32FBD | F + B + D | Face drilled holes, bond sensor and door position switch |
They stack in a fixed order, F then B then D. Read the letters left to right and each one adds what it says. This group has no bare M32 with no letters at all, so if you need one, ask us before you assume it is a stocked part.
B: the bond sensor
A magnalock with power on and an armature sitting a quarter inch off the magnet look identical from the power supply. Both draw current. Neither tells you the door will hold. The bond sensor answers that. It reports whether the armature is actually seated against the lock face, which is the one fact a lock cannot otherwise give the panel.
Want it on a door where the panel logs forced-door or held-open alarms, or where a bent door or a slightly racked frame has caused trouble before. Skip it on a door run from a timer and a pushbutton with nothing monitoring it. The sensor does nothing if no input is wired to read it.
D: the door position switch
The D is a door position switch. It tells the panel whether the door is open or closed, which is a different fact from whether the lock is holding. A door can be closed with the lock off, and a door can be open with the lock energized. A panel that logs door-held-open needs the D. A panel that needs to know the magnet is truly bonded needs the B. A monitored opening that wants both gets the BD.
If you only need a stand-alone switch on an existing lock, there is a separate part for that. Our DPS-M and DPS-W article covers it. Buying a D lock instead is the cleaner install: the switch is inside the lock and does not add a second device to the frame.
F: face drilled holes
The F is face drilled holes in the lock body, per every catalog name that carries it. Our listings say nothing more. We do not have the factory drawing of the hole pattern, so we will not describe it. Our M32 bracket article lists the Z-bracket kit for an inswing door with an F-type lock, which tells you the F matters when the lock hangs off a bracket instead of sitting flat on the header.
It is a mounting choice, not a performance one. The F and non-F parts share the 600 lb rating. If your door needs an F, the part number has to say F, because the F is part of the lock, not a loose option.
Picking the letter set for the door
- Timer and a pushbutton, nothing monitored: the plainest part that suits the mounting. Do not pay for sensors nothing reads.
- Panel logs door status only: D.
- Panel must confirm the magnet is bonded: B.
- Fully monitored opening: BD, or FBD if the door also needs the F.
- Header or bracket needs the face drilled holes: any F part, with the sensors you need after it.
Decide on the letters before you order. The sensors and the F holes are part of the lock, not accessories, so adding one later means buying a different part number.
About the fire rating
Every one of the seven listings carries the feature line "Fire Rated Grade 1 Door Hardware," and most of the titles say fire rated. None gives a listing number, a rating period or a door type. Treat the line as the listing's claim, not a substitute for the label on your door and frame. For a rated opening, confirm the hardware against the door label and your local inspector before you order, and tell us what the opening is if you want a second pair of eyes.
If you pair the lock with a power supply, a REX and a release, our power supply article covers that side.
Common questions
What does the B stand for on an M32B?
Magnetic bond sensor, per the catalog name.
What does the D stand for?
Door position switch.
What does the F stand for?
Face drilled holes.
Do the suffix letters change the holding force?
No. All seven listings give 600 lb.
Does the M32 need 12 volts or 24 volts?
Either. The listings say automatic dual voltage, with no field adjustment.
Can I add a sensor to an M32 later?
Not to the lock. The B and D parts are sold as complete locks. A stand-alone door position switch is a separate part.
How much current does an M32 draw?
Our listings do not give it. Check the installation sheet before you size the supply.